TRANSFORMER UNIT

Product information and specifications

1. Specifications

1) Name: SEAM WELDER INVERTER SYSTEM

2) General specifications

ItemSpecificationRemarks
InputInput voltageV440 (±10%)
PhaseΦ3
FrequencyHz50/60
CapacitykVA300
OutputPeak currentkA30
Load voltageV2–3
Load currentA3,000–30,000
No-load voltageV15–18
Duty cycle30 s / 5 minAmbient 25 °C
Power device controlFrequencykHz1.6
Duty%10–80
InterfaceControl signalsAnalogmA4–20Output current command
ONStartContact signal
OFFStopContact signal
Status outputsAnalogmA4–20Output current indication
ReadyOperating statusExternal contact
ErrorFault statusExternal contact

3) Details by section

◆ Rectifier section
- Uses SCRs with phase control for a soft-start function.
- Suppresses inrush current, allowing a smaller and lighter product.

◆ Inverter section
- Uses fast-switching IGBTs for quick control response.
- High-voltage-rated devices improve product safety.

◆ Control section
- A high-speed microprocessor provides fast control.

CONVERTER-PANELINVERTER-PANELRECTIFIER-UNITTRANSFORMER UNIT
CONVERTER-PANELINVERTER-PANELRECTIFIER-UNITTRANSFORMER UNIT